Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Clin Gastroenterol Hepatol ; 18(13): 2971-2979.e3, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32348907

RESUMO

BACKGROUND & AIMS: Inter-platform variation in liver stiffness evaluation (LSE) could hinder dissemination and clinical implementation of new ultrasound methods. We aimed to determine whether measurements of liver stiffness by bi-dimensional shear wave elastography (2D-SWE) with a Supersonic Imagine apparatus are comparable to those made by vibration-controlled transient elastography (VCTE). METHODS: We collected data from 1219 consecutive patients with chronic liver disease who underwent LSE by VCTE and 2D-SWE (performed by blinded operators), on the same day, at a single center in France from September 2011 through June 2019. We assessed the ability of liver stiffness value distributions and 2D-SWE performances to identify patients with compensated advanced chronic liver disease (cACLD) according to the Baveno VI criteria, based on VCTE cut-off values. RESULTS: VCTE and 2D-SWE values correlated (Pearson's correlation coefficient, 0.882; P < .0001; Lin concordance coefficient, 0.846; P < .0001). The median stiffness values were 6.7 kPa with VCTE (interquartile range, 4.8-11.6 kPa) and 7.1 kPa with 2D-SWE (interquartile range, 5.4-11.1 kPa) (P = .736). 2D-SWE values were slightly higher in the low percentiles and lower in the high percentiles; the best match with VCTE values were at approximately 7-9 kPa. The area under the curve of 2D-SWE for identifying of VCTE values below 10 was 0.964 (95% CI, 0.952-0.976) and for VCTE values above 15 kPa was 0.976 (95% CI, 0.963-0.988), with Youden index-associated cut-off values of 9.5 and 13kPa and best accuracy cut-off values of 10 kPa and 14 kPa, respectively. A 2D-SWE cut-off value of 10 kPa detected VCTE values below 10k Pa with 92% sensitivity, 87% specificity, and 91% accuracy. CONCLUSIONS: Measurement of liver stiffness by VCTE or 2D-SWE produces comparable results. 2D-SWE accurately identifies patients with cACLD according to the Baveno VI criteria based on VCTE cut-off values. A 10 kPa 2D-SWE cut-off value can be used to rule out cACLD.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatias , França , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/patologia , Hepatopatias/diagnóstico por imagem , Hepatopatias/patologia
2.
Clin Gastroenterol Hepatol ; 18(12): 2843-2845.e2, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-31574313

RESUMO

Because only a minority of patients with nonalcoholic fatty liver disease (NAFLD) have advanced fibrosis and would eventually develop liver-related complications, current guidelines recommend initial assessment with noninvasive tests of fibrosis.1-3 Most previous studies focused on overweight and obese patients. Despite a strong association between obesity and NAFLD, 3%-30% of people with relatively normal body mass index (BMI) may still have NAFLD.4,5 Hence, this study aims to evaluate the performance of the common noninvasive tests in non-obese (BMI <25 kg/m2) and obese (BMI ≥25 kg/m2) NAFLD patients.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Índice de Massa Corporal , Humanos , Cirrose Hepática/complicações , Hepatopatia Gordurosa não Alcoólica/complicações , Obesidade/complicações , Sobrepeso
3.
Liver Int ; 40(3): 581-589, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31749300

RESUMO

BACKGROUND AND AIMS: In non-alcoholic fatty liver disease (NAFLD), fibrosis is the strongest prognostic factor and can be assessed by non-invasive methods. We evaluated the ability of liver stiffness measurement (LSM) to predict overall survival and liver, cardiovascular and oncologic complications. METHODS: We prospectively collected data on 2251 consecutive NAFLD patients (mean age 59 years, male 53%, mean body mass index 28 kg/m2 ) in two centres. At inclusion, all patients had LSM, clinical and biological evaluation. During follow-up, we recorded cardiovascular events, cancers, liver complications, liver transplantation and death. The primary endpoint was overall survival. Survival curves according to LSM were first performed using Kaplan-Meier method for the primary endpoint, and Aalen-Johansen method for secondary outcomes to take into account competitive risks. In a second step, a Cox proportional hazard model analysis was done to identify independent predictors of overall survival. RESULTS: Median follow-up was 27 months [IQR: 25-38]. Fifty-five patients died and three patients had liver transplantation. Overall survival significantly decreased as baseline LSM increased. Twenty-one patients (0.9%) had a liver event, 142 (6.3%) developed cancer (excluding HCC) and 151 (6.7%) had a cardiovascular event during follow-up. By multivariable analysis, independent predictors of overall survival were as follows: baseline LSM (adjusted HR (aHR) = 2.85 [1.65-4.92], P = .0002), age (aHR = 1.11 [1.08-1.13], P < .0001) and male sex (aHR = 2.05 [1.17-3.57], P = .012). Patients with elevated LSM were also more likely to develop cardiovascular, and liver events but not other cancers. CONCLUSION: LSM can be used to predict survival, cardiovascular and liver complications in NAFLD patients.


Assuntos
Carcinoma Hepatocelular , Técnicas de Imagem por Elasticidade , Neoplasias Hepáticas , Hepatopatia Gordurosa não Alcoólica , Carcinoma Hepatocelular/patologia , Humanos , Fígado/patologia , Cirrose Hepática/patologia , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/complicações , Hepatopatia Gordurosa não Alcoólica/patologia
4.
Am J Gastroenterol ; 114(6): 916-928, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31169533

RESUMO

INTRODUCTION: Some evidence suggests an interference of obesity and alanine aminotransferase (ALT) levels on the diagnostic accuracy for advanced fibrosis of noninvasive tools such as liver stiffness measurement (LSM) by FibroScan, Fibrosis-4 (FIB-4), and nonalcoholic fatty liver disease fibrosis score (NFS). We assessed whether the diagnostic accuracy of LSM, Fibrosis-4 (FIB-4), and NFS and strategies based on the combination of these tools is affected by obesity and/or ALT levels. METHODS: We analyzed data from 968 patients with a histological diagnosis of nonalcoholic fatty liver disease. FIB-4, NFS, and LSM by FibroScan were measured. RESULTS: LSM was better than both FIB-4 and NFS for staging F3-F4 fibrosis area under the receiver operating characteristic curve test (AUC) 0.863, 0.777, and 0.765, respectively; P < 0.001 for both), showing higher accuracy and higher negative predictive value (NPV), but lower positive predictive value (PPV). LSM worked less well in high ALT (>100 IU) (AUC 0.811 vs 0.877, P = 0.04; PPV 57.5% vs 62.4%; NPV 90.7% vs 94%) or obese patients (AUC 0.786 vs 0.902, P < 0.001; PPV 58.7% vs 64.8%; NPV 88.3% vs 95.2%), the latter not being affected by the M or XL probe. Consistently, LSM worked better in terms of AUC and accuracy compared with both FIB-4 and NFS only in nonobese or high ALT patients, even with always keeping a slightly lower PPV. A serial combination of FIB-4 or NFS with LSM as the second test in patients in the gray area of the first test retained-in most scenarios-similar PPV and NPV compared with LSM alone. These strategies also increased the diagnostic accuracy of about 20% in all groups of patients, even if with a lower overall accuracy in obese patients (71.3% and 67.1% for FIB-4 and NFS as the first test, respectively) compared to nonobese patients (81.9% and 82.4% for FIB-4 and NFS as the first test, respectively). CONCLUSIONS: All tested noninvasive tools have overall better NPV than PPV. LSM has a better diagnostic accuracy for advanced fibrosis than both FIB-4 and NFS only in nonobese and/or low ALT patients. Serial combination strategies are better than a single tool strategy, regardless of obesity and ALT levels, although the accuracy is lower in obese patients.


Assuntos
Alanina Transaminase/sangue , Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/etiologia , Fígado/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/complicações , Obesidade/complicações , Aspartato Aminotransferases/sangue , Biomarcadores/sangue , Biópsia , Feminino , Humanos , Cirrose Hepática/diagnóstico , Cirrose Hepática/enzimologia , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/diagnóstico , Hepatopatia Gordurosa não Alcoólica/enzimologia , Obesidade/enzimologia , Valor Preditivo dos Testes , Curva ROC , Índice de Gravidade de Doença
5.
J Hepatol ; 71(2): 389-396, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31102719

RESUMO

BACKGROUND & AIMS: Advanced liver fibrosis is an important diagnostic target in non-alcoholic fatty liver disease (NAFLD) as it defines the subgroup of patients with impaired prognosis. The non-invasive diagnosis of advanced fibrosis is currently limited by the suboptimal positive predictive value and the grey zone (representing indeterminate diagnosis) of fibrosis tests. Here, we aimed to determine the best combination of non-invasive tests for the diagnosis of advanced fibrosis in NAFLD. METHODS: A total of 938 patients with biopsy-proven NAFLD were randomized 2:1 into derivation and validation sets. All patients underwent liver stiffness measurement with vibration controlled transient elastography (VCTE) and blood fibrosis tests (NAFLD fibrosis score, Fibrosis-4 [FIB4], Fibrotest, Hepascore, FibroMeter). FibroMeterVCTE, which combines VCTE results and FibroMeter markers in a single test, was also calculated in all patients. RESULTS: For the diagnosis of advanced fibrosis, VCTE was significantly more accurate than the blood tests (area under the receiver operating characteristic curve [AUROC]: 0.840 ±â€¯0.013, p ≤0.005). FibroMeter was the most accurate blood test (AUROC: 0.793 ±â€¯0.015, p ≤0.017). The combinatory test FibroMeterVCTE outperformed VCTE and blood tests (AUROC: 0.866 ±â€¯0.012, p ≤0.005). The sequential combination of FIB4 then FibroMeterVCTE (FIB4-FMVCTE algorithm) or VCTE then FibroMeterVCTE (VCTE-FMVCTE algorithm) provided an excellent diagnostic accuracy of 90% for advanced fibrosis, with liver biopsy only required to confirm the diagnosis in 20% of cases. The FIB4-FMVCTE and VCTE-FMVCTE algorithms were significantly more accurate than the pragmatic algorithms currently proposed. CONCLUSION: The sequential combination of fibrosis tests in the FIB4-FMVCTE and VCTE-FMVCTE algorithms provides a highly accurate solution for the diagnosis of advanced fibrosis in NAFLD. These algorithms should now be validated for the diagnosis of advanced liver fibrosis in diabetology or primary care settings. LAY SUMMARY: The evaluation of liver fibrosis is mandatory in non-alcoholic fatty liver disease (NAFLD), as advanced fibrosis identifies the subgroup of patients with impaired prognosis. FibroMeterVCTE is a new fibrosis test combining blood markers and the result of vibration controlled transient elastography (VCTE) into a single diagnostic test. Our results show that FibroMeterVCTE outperforms other blood fibrosis tests and VCTE alone for the diagnosis of advanced fibrosis in a large multi-centric cohort of 938 patients with biopsy-proven NAFLD. Sequential algorithms using a simple blood test or VCTE as a first-line procedure, then FibroMeterVCTE as a second-line test accurately classified 90% of patients.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Testes Hematológicos/métodos , Cirrose Hepática/diagnóstico , Cirrose Hepática/etiologia , Hepatopatia Gordurosa não Alcoólica/complicações , Adulto , Idoso , Algoritmos , Biomarcadores/sangue , Biópsia , Estudos de Coortes , Confiabilidade dos Dados , Feminino , Humanos , Fígado/patologia , Cirrose Hepática/sangue , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/sangue , Prognóstico , Distribuição Aleatória
6.
Gut ; 68(11): 2057-2064, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-30658997

RESUMO

OBJECTIVE: The latest model of vibration-controlled transient elastography (VCTE) automatically selects M or XL probe according to patients' body built. We aim to test the application of a unified interpretation of VCTE results with probes appropriate for the body mass index (BMI) and hypothesise that this approach is not affected by hepatic steatosis. DESIGN: We prospectively recruited 496 patients with non-alcoholic fatty liver disease who underwent VCTE by both M and XL probes within 1 week before liver biopsy. RESULTS: 391 (78.8%) and 433 (87.3%) patients had reliable liver stiffness measurement (LSM) (10 successful acquisitions and IQR:median ratio ≤0.30) by M and XL probes, respectively (p<0.001). The area under the receiver operating characteristic curves was similar between the two probes (0.75-0.88 for F2-4, 0.83-0.91 for F4). When used in the same patient, LSM by XL probe was lower than that by M probe (mean difference 2.3 kPa). In contrast, patients with BMI ≥30 kg/m2 had higher LSM regardless of the probe used. When M and XL probes were used in patients with BMI <30 and ≥30 kg/m2, respectively, they yielded nearly identical median LSM at each fibrosis stage and similar diagnostic performance. Severe steatosis did not increase LSM or the rate of false-positive diagnosis by XL probe. CONCLUSION: High BMI but not severe steatosis increases LSM. The same LSM cut-offs can be used without further adjustment for steatosis when M and XL probes are used according to the appropriate BMI.


Assuntos
Técnicas de Imagem por Elasticidade , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia , Adulto , Idoso , Índice de Massa Corporal , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes
7.
Eur J Gastroenterol Hepatol ; 30(5): 569-577, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29406435

RESUMO

BACKGROUND: One of the unmet needs in patients with metabolic risks is the prediction of metabolic liver disease (MLD) by noninvasive tests (NITs). OBJECTIVE: The primary aim of this study was to construct a new quantitative test for the diagnosis of nonalcoholic steatohepatitis (NASH) using a simplified histological definition. PATIENTS AND METHODS: As a reference, we used a simplified histological definition of NASH derived from the FLIP-CRN-definition that does not require the presence of steatosis and the presence of both lobular inflammation and ballooning. We analyzed 1081 patients from two prospective cohorts at risk of MLD who had biopsies and contemporaneous blood samples. These patients were divided randomly into a training group (n=541) and a control group (n=540) for internal validation. The new test was compared with standard tests, and applied in two large populations at risk of MLD. RESULTS: Out of 1081 patients with biopsy, 39 (3.6%) cases with significant inflammatory activity or fibrosis (A2orF2) were missed by the current histological definitions. The combination of 11 parameters permitted to construct a test (NIT-NASHs) predicting NASH with an area under the receiver operating characteristic curve (AUROC) of 0.773 (95% confidence interval: 0.730-0.810), confirmed in the control group 0.814 (0.774-0.847). The AUROCs of NIT-NASHs were higher (all P<0.001) than those of ActiTest, FIB4, BARD, and nonalcoholic fatty liver disease scores. A combination of NIT-NASHs with FibroTest (AUROC=0.800; 0.759-0.835) enabled a better prediction (P<0.0001) of significant MLD, A2orF2, than the ActiTest-FibroTest combination. CONCLUSION: These results suggested that this new test enables a quantitative assessment of NASH, and when associated with the FibroTest, identifies cases with clinically significant MLD. An external validation is needed.


Assuntos
Hepatopatia Gordurosa não Alcoólica/diagnóstico , Adulto , Idoso , Biomarcadores/sangue , Biópsia , Feminino , França/epidemiologia , Humanos , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/epidemiologia , Hepatopatia Gordurosa não Alcoólica/patologia , Estudos Prospectivos , Distribuição Aleatória , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença
8.
Dig Dis Sci ; 62(9): 2569-2577, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28577247

RESUMO

INTRODUCTION: Controlled attenuation parameter (CAP) is a new method for the diagnosis of steatosis. Until now, CAP was available only with the M probe of the Fibroscan. The aim of this study was to evaluate the diagnostic performance of CAP with the XL probe versus CAP with the M probe, using liver biopsy (LB) as gold standard. PATIENTS AND METHODS: A total of 236 patients with chronic liver disease undergoing LB had CAP measurement with M and XL probes the same day. All LB were analyzed independently by two experienced pathologists. RESULTS: Median CAP was 240.5 and 239.5 dB/m with the M and XL probes, respectively. For the detection of steatosis grade with the M and XL probes, AUROCs were 0.82/0.83 for S ≥ 1, 0.89/0.88 for S ≥ 2, and 0.92/0.93 for S3, respectively. Cutoffs were (M and XL probes) 246/242 for S ≥ 1, 269/267 for S ≥ 2, and 285/286 dB/m for S3, respectively. The factor significantly associated with CAP with the M and XL probes was steatosis grade. In multivariate analysis, a low CAP value with XL probe was negatively associated with waist circumference, triglycerides, albumin, and the alcohol consumption, and positively with alkaline phosphatases. In multivariate analysis, a high CAP value with the XL probe was positively associated with waist circumference and triglycerides. CONCLUSION: CAP with the XL probe is a new tool for the diagnosis of steatosis. This parameter could be useful for the diagnosis and the follow-up of obese patients.


Assuntos
Doença Hepática Terminal/diagnóstico por imagem , Doença Hepática Terminal/fisiopatologia , Ultrassonografia/instrumentação , Adulto , Idoso , Área Sob a Curva , Biópsia , Feminino , Humanos , Masculino , Doenças Metabólicas/diagnóstico por imagem , Doenças Metabólicas/fisiopatologia , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/fisiopatologia , Estudos Prospectivos , Estudos Retrospectivos , Ultrassonografia/normas
9.
J Hepatol ; 67(3): 577-584, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28506907

RESUMO

BACKGROUND & AIMS: Controlled attenuation parameter (CAP) can be performed together with liver stiffness measurement (LSM) by transient elastography (TE) and is often used to diagnose fatty liver. We aimed to define the validity criteria of CAP. METHODS: CAP was measured by the M probe prior to liver biopsy in 754 consecutive patients with different liver diseases at three centers in Europe and Hong Kong (derivation cohort, n=340; validation cohort, n=414; 101 chronic hepatitis B, 154 chronic hepatitis C, 349 non-alcoholic fatty liver disease, 37 autoimmune hepatitis, 49 cholestatic liver disease, 64 others; 277 F3-4; age 52±14; body mass index 27.2±5.3kg/m2). The primary outcome was the diagnosis of fatty liver, defined as steatosis involving ≥5% of hepatocytes. RESULTS: The area under the receiver-operating characteristics curve (AUROC) for CAP diagnosis of fatty liver was 0.85 (95% CI 0.82-0.88). The interquartile range (IQR) of CAP had a negative correlation with CAP (r=-0.32, p<0.001), suggesting the IQR-to-median ratio of CAP would be an inappropriate validity parameter. In the derivation cohort, the IQR of CAP was associated with the accuracy of CAP (AUROC 0.86, 0.89 and 0.76 in patients with IQR of CAP <20 [15% of patients], 20-39 [51%], and ≥40dB/m [33%], respectively). Likewise, the AUROC of CAP in the validation cohort was 0.90 and 0.77 in patients with IQR of CAP <40 and ≥40dB/m, respectively (p=0.004). The accuracy of CAP in detecting grade 2 and 3 steatosis was lower among patients with body mass index ≥30kg/m2 and F3-4 fibrosis. CONCLUSIONS: The validity of CAP for the diagnosis of fatty liver is lower if the IQR of CAP is ≥40dB/m. Lay summary: Controlled attenuation parameter (CAP) is measured by transient elastography (TE) for the detection of fatty liver. In this large study, using liver biopsy as a reference, we show that the variability of CAP measurements based on its interquartile range can reflect the accuracy of fatty liver diagnosis. In contrast, other clinical factors such as adiposity and liver enzyme levels do not affect the performance of CAP.


Assuntos
Fígado Gorduroso/diagnóstico , Adulto , Idoso , Biópsia , Estudos Transversais , Técnicas de Imagem por Elasticidade , Feminino , Humanos , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes
10.
Hepatology ; 65(4): 1145-1155, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27639088

RESUMO

Liver stiffness measurement (LSM) frequently overestimates the severity of liver fibrosis in nonalcoholic fatty liver disease (NAFLD). Controlled attenuation parameter (CAP) is a new parameter provided by the same machine used for LSM and associated with both steatosis and body mass index, the two factors mostly affecting LSM performance in NAFLD. We aimed to determine whether prediction of liver fibrosis by LSM in NAFLD patients is affected by CAP values. Patients (n = 324) were assessed by clinical and histological (Kleiner score) features. LSM and CAP were performed using the M probe. CAP values were grouped by tertiles (lower 132-298, middle 299-338, higher 339-400 dB/m). Among patients with F0-F2 fibrosis, mean LSM values, expressed in kilopascals, increased according to CAP tertiles (6.8 versus 8.6 versus 9.4, P = 0.001), and along this line the area under the curve of LSM for the diagnosis of F3-F4 fibrosis was progressively reduced from lower to middle and further to higher CAP tertiles (0.915, 0.848-0.982; 0.830, 0.753-0.908; 0.806, 0.723-0.890). As a consequence, in subjects with F0-F2 fibrosis, the rates of false-positive LSM results for F3-F4 fibrosis increased according to CAP tertiles (7.2% in lower versus 16.6% in middle versus 18.1% in higher). Consistent with this, a decisional flowchart for predicting fibrosis was suggested by combining both LSM and CAP values. CONCLUSIONS: In patients with NAFLD, CAP values should always be taken into account in order to avoid overestimations of liver fibrosis assessed by transient elastography. (Hepatology 2017;65:1145-1155).


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/tendências , Cirrose Hepática/patologia , Hepatopatia Gordurosa não Alcoólica/patologia , Adulto , Fatores Etários , Idoso , Análise de Variância , Biópsia por Agulha , Estudos de Coortes , Feminino , Humanos , Imuno-Histoquímica , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Melhoria de Qualidade , Curva ROC , Medição de Risco , Sensibilidade e Especificidade , Fatores Sexuais
11.
J Gastroenterol Hepatol ; 31(4): 848-55, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26514665

RESUMO

BACKGROUND AND AIM: Controlled attenuation parameter (CAP) evaluated with transient elastography (FibroScan) is a recent method for non-invasive assessment of steatosis. Its usefulness in non-alcoholic fatty liver disease (NAFLD) is unknown. We prospectively investigated the performance of CAP for the diagnosis of steatosis in NAFLD, factors associated with discordances between CAP and steatosis grades, and relationships between CAP and clinical or biological parameters. METHODS: All CAP examinations performed in NAFLD patients with a liver biopsy performed within 1 week of CAP measurement were included. Liver biopsies were assessed for activity and fibrosis stage, NAFLD activity score, and steatosis graded as follows: S0, steatosis < 5%; S1, 5-33%; S2, 34-66%; S3, >66%. RESULTS: Two hundred sixty-one patients (59% male, age 56 years) from two ethnic groups were included. No patient had steatosis < 5%. The area under the receiver-operating characteristics curve of CAP for steatosis ≥S2 and S3 was 0.80 and 0.66, respectively. At a cut-off value of 310 dB/m, the sensitivity, specificity, and positive and negative predictive values for ≥S2 steatosis were 79%, 71%, 86%, and 71%, respectively. Discordance of at least one grade between CAP and steatosis was observed in 81 patients. By multivariate analysis, only steatosis S2S3 was associated with no discordance. By multivariate analysis, only BMI ≥ 30 kg/m(2) was significantly associated with CAP > 310 dB/m. CONCLUSION: The association of CAP with steatosis, especially in patients with non-alcoholic steatohepatitis, and with elevated BMI could be useful for the diagnosis and follow-up of NAFLD patients.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Fígado Gorduroso/diagnóstico por imagem , Fígado/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Adulto , Idoso , Biópsia , Índice de Massa Corporal , Fígado Gorduroso/patologia , Feminino , Humanos , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Hepatopatia Gordurosa não Alcoólica/patologia , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade
12.
J Hepatol ; 61(5): 994-1003, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25016224

RESUMO

BACKGROUND & AIMS: The first aim was to extend the validation of FibroTest® (FT) and transient elastography (TE) as markers of occurrence of cirrhosis without complications (F4.1), oesophageal varices (F4.2), and severe complications (F4.3) in patients with chronic hepatitis B (CHB). The second aim was to validate a previous definition of an inactive carrier based on normal FT and ActiTest® (normal-FT-AT). The third aim was to assess the long-term dynamics of fibrosis in patients with sustained virological response. METHODS: The 10-year updated individual data of 1434 patients were pooled from two prospective cohorts. RESULTS: Of the 1312 patients without a history of complications, varices had occurred after 10 years in 14 patients (F4.2, incidence of 1.7%, 95% CI [0.6-2.8]), and severe complications in 25 (F4.3 3.7% [1.8-5.7]), including hepatocellular carcinoma (HCC) in 21 (3.7% [1.5-5.8]). Using Cox-multivariate analysis adjusted for treatment, viral load, HBeAg status and ALT, FT, and TE were predictive of liver complications (n=37; AUROC=0.83 [0.71-0.90]; p<0.0001) and (n=8/844; AUROC=0.82 [0.72-0.89]; p<0.0001) respectively. Normal FT-AT better identified patients with lower fibrosis progression than the ALT-based standard: 3/163 (1.8%) vs. 16/181 (8.8%; p=0.004) in the Paris cohort, and 5/195 (2.6%) vs. 15/228 (6.6%; p=0.05) in the Bordeaux cohort. Of the 582 responders, 23 had complications (incidence 6.2% [3.2-9.1]) including 19 HCC (5.8% [2.6-9.0]) and 10 with varices (2.6% [0.8-4.4]). Of the 138 responders with advanced fibrosis, only 31% (15-47%) had fibrosis regression. CONCLUSIONS: FibroTest® and TE identified three categories of cirrhosis with increasing morbidity. Normal FibroTest® and ActiTest® were better able to identify inactive hepatitis B carriers than the standard definition. Despite virological response, the overall incidence of cirrhosis increased, with a remaining 5.8% risk of HCC.


Assuntos
Hepatite B Crônica/classificação , Adulto , Biomarcadores/sangue , Carcinoma Hepatocelular/etiologia , Portador Sadio/sangue , Portador Sadio/diagnóstico , Estudos de Coortes , Progressão da Doença , Técnicas de Imagem por Elasticidade , Varizes Esofágicas e Gástricas/etiologia , Feminino , Hepatite B Crônica/complicações , Hepatite B Crônica/diagnóstico , Humanos , Cirrose Hepática/sangue , Cirrose Hepática/diagnóstico , Neoplasias Hepáticas/etiologia , Masculino , Estudos Prospectivos , Carga Viral
13.
Hepatology ; 60(1): 65-76, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24519328

RESUMO

UNLABELLED: No data are available about the prediction of long-term survival using repeated noninvasive tests of liver fibrosis in chronic hepatitis C (CHC). We aimed to assess the prognostic value of 3-year liver stiffness measurement (LSM), aspartate aminotransferase to platelet ratio index (APRI), and fibrosis 4 (FIB-4) evolution in CHC. CHC patients with two LSM (1,000-1,500 days interval) were prospectively included. Blood fibrosis tests APRI and FIB-4 were calculated the day of baseline (bLSM) and follow-up (fLSM) LSM. Evolution of fibrosis tests was expressed as delta: (follow-up-baseline results)/duration. Date and cause of death were recorded during follow-up that started the day of fLSM. In all, 1,025 patients were included. Median follow-up after fLSM was 38.0 months (interquartile range [IQR]: 27.7-46.1) during which 35 patients died (14 liver-related death) and seven had liver transplantation. Prognostic accuracy (Harrell C-index) of multivariate models including baseline and delta results was not significantly different between LSM and FIB-4 (P ≥ 0.24), whereas FIB-4 provided more accurate prognostic models than APRI (P = 0.03). By multivariate analysis including LSM variables, overall survival was independently predicted by bLSM, delta (dLSM), and sustained virological response (SVR). Prognosis was excellent in patients having bLSM <7 kPa, SVR, or no increase (<1 kPa/year) in 7-14 kPa bLSM. Prognosis was significantly impaired in patients with an increase (≥ 1 kPa/year) in 7-14 kPa bLSM, or decrease (≤ 0 kPa/year) in ≥ 14 kPa bLSM (P = 0.949 between these two groups). Patients with an increase (>0 kPa/year) in ≥ 14 kPa bLSM had the worst prognosis. Baseline and delta FIB-4 also identified patient subgroups with significantly different prognosis. CONCLUSION: Three-year evolution of noninvasive tests of liver fibrosis has a strong prognostic value in CHC patients. These tests should be repeated to monitor patients and predict their outcome.


Assuntos
Hepatite C Crônica/diagnóstico , Hepatite C Crônica/mortalidade , Cirrose Hepática/diagnóstico , Cirrose Hepática/mortalidade , Adulto , Idoso , Aspartato Aminotransferases/sangue , Biomarcadores/sangue , Progressão da Doença , Técnicas de Imagem por Elasticidade , Feminino , Seguimentos , Hepatite C Crônica/metabolismo , Humanos , Estimativa de Kaplan-Meier , Cirrose Hepática/virologia , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Contagem de Plaquetas , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Fatores de Risco
14.
J Hepatol ; 60(5): 1026-31, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24378529

RESUMO

BACKGROUND & AIMS: Controlled attenuation parameter (CAP) evaluated with transient elastography (FibroScan®) is a recent method for non-invasive assessment of steatosis. Its usefulness in clinical practice is unknown. We prospectively investigated the determinants of CAP failure and the relationships between CAP and clinical or biological parameters in a large cohort of consecutive patients. METHODS: All CAP examinations performed in adult patients with suspected chronic liver disease were included. CAP failure was defined as zero valid shot. The following factors were analyzed for their influence on CAP value and the relationships between CAP and clinico-biological parameters: age, gender, body mass index, waist circumference, hypertension, diabetes, metabolic syndrome, alcohol use, liver stiffness measurement, indication, and different biological parameters. RESULTS: CAP failure occurred in 7.7% of 5323 examinations. By multivariate analysis, factors independently associated with CAP measurement failure were female gender, BMI, and metabolic syndrome. By multivariate analysis, factors significantly associated with elevated CAP were BMI [25-30]kg/m(2), BMI >30kg/m(2), metabolic syndrome, alcohol >14 drink/week and liver stiffness >6kPa. CAP increased with the number of parameters of metabolic syndrome, BMI, waist circumference, the presence of diabetes or hypertension, and the cause of the disease. In the 440 patients with liver biopsy, for the diagnosis of steatosis >10%, steatosis >33%, and steatosis >66%, AUROCs of CAP were 0.79 (95% CI 0.74-0.84, p<0.001), 0.84 (95% CI 0.80-0.88, p<0.001), 0.84 (95% CI 0.80-0.88, p<0.001), respectively. CONCLUSIONS: CAP provides an immediate assessment of steatosis simultaneously with liver stiffness measurement. The strong association of CAP with the metabolic syndrome and alcohol use could be of interest for the follow-up of NAFLD or alcoholic patients.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Fígado Gorduroso/diagnóstico por imagem , Adulto , Idoso , Alcoolismo/complicações , Índice de Massa Corporal , Estudos de Coortes , Erros de Diagnóstico , Elasticidade , Fígado Gorduroso/etiologia , Fígado Gorduroso/fisiopatologia , Fígado Gorduroso Alcoólico/diagnóstico por imagem , Feminino , Humanos , Masculino , Síndrome Metabólica/complicações , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Estudos Prospectivos , Fatores de Risco
15.
J Hepatol ; 60(4): 706-14, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24291240

RESUMO

BACKGROUND & AIMS: FibroTest™ (FT) and Transient Elastography (TE) have been validated as non-invasive markers of METAVIR fibrosis stages from F0 to F4 using biopsy, and as prognostic markers of liver related mortality in patients with chronic hepatitis C. The aim was to extend the validation of FT and TE as markers of critical steps defined by occurrence of cirrhosis without complications (F4.1), esophageal varices (F4.2), and severe complications (F4.3): primary liver cancer, variceal bleeding, or decompensation (ascites, encephalopathy, or jaundice). METHODS: The updated individual data of 3927 patients (1046 cirrhotics) without complications at baseline were pooled from three prospective cohorts called "EPIC", "Paris", and "Bordeaux" cohorts. RESULTS: At 5 years, among 501 patients without varices at baseline (F4.1) varices occurred in 19 patients [F4.2 incidence of 4.0% (95% CI 2.2-5.8)]. The predictive performance (AUROC) of FT was 0.77 (0.66-0.84; p<0.001). At 10 years severe complications occurred in 203 patients, [F4.3 incidence of 13.4% (9.6-17.1)], including primary liver cancer in 84 patients [6.4% (3.5-9.3)]. FT was predictive (Cox adjusted on treatment) of severe complications [AUROC 0.79 (76-82); p<0.0001], including primary liver cancer [AUROC 0.84 (80-87); p<0.0001]. Similarly TE was predictive of severe complications [AUROC 0.77 (72-81); p<0.0001], including primary liver cancer [AUROC 0.86 (81-90); p<0.0001]. CONCLUSIONS: FibroTest™ and TE increase were associated with the occurrence of all severe complications including hepatocellular carcinoma, hepatic insufficiency, and variceal bleeding. FibroTest™ increase was also associated with the occurrence of esophageal varices.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Hepatite C Crônica/patologia , Cirrose Hepática/patologia , Carcinoma Hepatocelular/etiologia , Estudos de Coortes , Progressão da Doença , Varizes Esofágicas e Gástricas/diagnóstico , Varizes Esofágicas e Gástricas/etiologia , Feminino , Insuficiência Hepática/etiologia , Hepatite C Crônica/classificação , Hepatite C Crônica/complicações , Humanos , Cirrose Hepática/classificação , Cirrose Hepática/complicações , Neoplasias Hepáticas/etiologia , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos
16.
Ann Hepatol ; 12(4): 570-80, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23813135

RESUMO

UNLABELLED: BACKGROUND AND RATIONALE FOR THE STUDY: Limited studies have aimed to define the cut-offs of XL probe (XL cut-offs) for different stages of liver fibrosis, whereas those of M probe (M cut-offs) may not be applicable to XL probe. We aimed to derive appropriate XL cut-offs in overweight patients. Patients with liver stiffness measurement (LSM) by both probes were recruited. XL cut-offs probe for corresponding M cut-offs were derived from an exploratory cohort, and subsequently validated in a subgroup patients also underwent liver biopsy. The diagnostic accuracy of XL cut-offs to diagnose advanced fibrosis was evaluated. RESULTS: Total 517 patients (63% male, mean age 58) who had reliable LSM by both probes were included in the exploratory cohort. There was a strong correlation between the LSM by M probe (LSM-M) and LSM by XL probe (LSM-XL) (r² = 0.89, p < 0.001). A decision tree using LSM-XL was learnt to predict the 3 categories of LSM-M (< 6.0kPa, 6.0-11.9kPa and ≥ 12.0kPa), and XL cut-offs at 4.8kPa and 10.7kPa were identified. These cut-offs were subsequently validated in a cohort of 147 patients who underwent liver biopsy. The overall accuracy was 89% among 62 patients whose LSM-XL < 4.8kPa or ≥ 10.7kPa. These cut-offs would have avoided under-staging of fibrosis among patients with body mass index (BMI) > 25-30 kg/m2 but not > 30 kg/m2. CONCLUSIONS: XL cut-offs at 4.8kPa and 10.7kPa were the best estimates of 6.0kPa and 12.0kPa of M probe for patients with BMI > 25-30 kg/m2. Patients with BMI > 30 kg/m² might use M probe cut-offs for XL probe.


Assuntos
Técnicas de Imagem por Elasticidade/instrumentação , Cirrose Hepática/diagnóstico por imagem , Fígado/diagnóstico por imagem , Adulto , Idoso , Algoritmos , Biópsia , Calibragem , Técnicas de Apoio para a Decisão , Árvores de Decisões , Módulo de Elasticidade , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/normas , Desenho de Equipamento , Feminino , França , Hong Kong , Humanos , Modelos Lineares , Fígado/patologia , Cirrose Hepática/complicações , Cirrose Hepática/patologia , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes
17.
Antivir Ther ; 18(5): 723-7, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23702639

RESUMO

BACKGROUND: Telaprevir (TVR) is a protease inhibitor (PI) used in chronic hepatitis C treatment with pegylated interferon plus ribavirin. We analysed the prevalence and kinetic development of TVR resistance upon treatment. METHODS: A total of 24 cirrhotic patients (genotype 1a, n=8; genotype 1b, n=16) previously non-responders to standard therapy were treated with TVR-based therapy. The distribution of TVR-resistant variants was assessed at every HCV-RNA-positive time point by 454 ultra-deep pyrosequencing (UDPS) during a mean follow-up period of 9.4 months. RESULTS: A median of 6,837 reads/specimen was studied. Based on control UDPS, we considered mutations as real when present >0.4%. TVR-resistant variants were found at baseline in 8/24 patients (33.3%). Four of the 24 patients (16.7%), all genotype 1a, did not achieve HCV RNA<100 IU/ml between week (W)2 and W12 and stopped treatment. No statistical significant difference was observed in the prevalence of resistant mutants between responders and non-responders (25% [5/20] and 75% [3/4], respectively). The proportion of genotype 1a patients with R155K/T/Q at baseline was higher in non-responders than in responders (50% versus 0%). During treatment failure, significant enrichment in V36A/M and R155K/T/Q was observed but their frequency reverted back to baseline after TVR discontinuation. CONCLUSIONS: TVR-resistant variants are widely present at baseline. The presence of TVR-resistant mutants at baseline, even in high abundance (>20%), did not always preclude TVR treatment success. The detection of R155K/T/Q at baseline may predict failure in genotype 1a patients. At failure, which occurred in genotype 1a patients, a significant enrichment in V36A/M and R155K/T/Q was observed.


Assuntos
Antivirais/uso terapêutico , Hepacivirus/genética , Hepatite C Crônica/tratamento farmacológico , Hepatite C Crônica/virologia , Oligopeptídeos/uso terapêutico , Idoso , Feminino , Seguimentos , Genótipo , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Masculino , Pessoa de Meia-Idade , Mutação , RNA Viral , Resultado do Tratamento , Carga Viral
18.
PLoS One ; 7(10): e47715, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23082200

RESUMO

BACKGROUND/AIMS: Liver stiffness (LS) measurement by means of transient elastography (TE) is accurate to predict fibrosis stage. The effect of antiviral treatment and virologic response on LS was assessed and compared with untreated patients with chronic hepatitis C (CHC). METHODS: TE was performed at baseline, and at weeks 24, 48, and 72 in 515 patients with CHC. RESULTS: 323 treated (62.7%) and 192 untreated patients (37.3%) were assessed. LS experienced a significant decline in treated patients and remained stable in untreated patients at the end of study (P<0.0001). The decline was significant for patients with baseline LS ≥ 7.1 kPa (P<0.0001 and P 0.03, for LS ≥ 9.5 and ≥ 7.1 kPa vs lower values, respectively). Sustained virological responders and relapsers had a significant LS improvement whereas a trend was observed in nonresponders (mean percent change -16%, -10% and -2%, for SVR, RR and NR, respectively, P 0.03 for SVR vs NR). In multivariate analysis, high baseline LS (P<0.0001) and ALT levels, antiviral therapy and non-1 genotype were independent predictors of LS improvement. CONCLUSIONS: LS decreases during and after antiviral treatment in patients with CHC. The decrease is significant in sustained responders and relapsers (particularly in those with high baseline LS) and suggests an improvement in liver damage.


Assuntos
Antivirais/uso terapêutico , Hepatite C Crônica/tratamento farmacológico , Hepatite C Crônica/fisiopatologia , Fígado/fisiopatologia , Antivirais/farmacologia , Técnicas de Imagem por Elasticidade , Feminino , Seguimentos , Hepatite C Crônica/complicações , Hepatite C Crônica/virologia , Humanos , Fígado/efeitos dos fármacos , Fígado/virologia , Cirrose Hepática/complicações , Cirrose Hepática/tratamento farmacológico , Cirrose Hepática/fisiopatologia , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade
19.
Am J Gastroenterol ; 107(12): 1862-71, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23032979

RESUMO

OBJECTIVES: Liver stiffness measurement (LSM) by transient elastography is a noninvasive test of liver fibrosis, but cannot be performed in a significant proportion of obese patients. The aim of this study was to evaluate the performance of the new XL probe in patients with nonalcoholic fatty liver disease (NAFLD). METHODS: Liver biopsy and paired LSM by both the original M probe and XL probe were performed on 193 consecutive NAFLD patients in France and Hong Kong. RESULTS: Compared with M probe, XL probe was more likely to achieve 10 valid measurements (95% vs. 81%; P<0.001) and a success rate of over 60% (90% vs. 74%; P<0.001). The areas under receiver operating characteristics curves of XL probe for F2, F3, and F4 disease were 0.80, 0.85, and 0.91, respectively. XL probe tended to generate lower LSM than M probe in the same patient. At a cutoff of 7.2 kPa, the sensitivity, specificity, positive, and negative predictive values for F3 or greater disease were 78%, 78%, 60%, and 89%, respectively. Discordance of at least two stages between XL probe and histology was observed in 16 (9%) patients. Body mass index (BMI) over 35 kg/m(2) was independently associated with discordance (adjusted odds ratio 9.09; 95% confidence interval 1.10-75.43). Reliable measurements by XL probe were obtained in 75% of the overall population and 65% of patients with BMI over 30 kg/m(2). CONCLUSIONS: LSM by XL probe can be performed successfully in most NAFLD patients, but obesity is associated with less accurate and reliable measurements.


Assuntos
Biópsia , Técnicas de Imagem por Elasticidade/instrumentação , Fígado Gorduroso/patologia , Cirrose Hepática/patologia , Adulto , Idoso , Área Sob a Curva , Índice de Massa Corporal , Fígado Gorduroso/fisiopatologia , Feminino , França , Hong Kong , Humanos , Cirrose Hepática/fisiopatologia , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica , Razão de Chances , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Liver Int ; 32(6): 911-8, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22672642

RESUMO

INTRODUCTION: Recently, a study showed that Controlled Attenuation Parameter (CAP), evaluated with transient elastography, could efficiently separate steatosis grades. The aim of this study was to prospectively evaluate the performance of CAP for the diagnosis of steatosis in patients with chronic liver disease. PATIENTS AND METHODS: Consecutive patients with chronic liver disease had steatosis diagnosis using CAP, blood sample and liver biopsy. Steatosis was graded as the percentage of hepatocytes with fat: S0 ≤ 10%, S1: 11 ~ 33%, S2: 34 ~ 66%, S3 ≥ 67%. RESULTS: Characteristics of the 112 patients included were as follows: age 54 years, BMI 26 kg m(-) ², HCV 36%, NAFLD 25%. Steatosis repartition was: S0 52%, S1 19%, S2 14%, S3 15%. CAP was significantly correlated with SteatoTest, Fatty Liver Index (FLI), percentage of steatosis on liver biopsy, steatosis grade and slightly with liver stiffness, but not with fibrosis and activity grade on liver biopsy. Using CAP vs SteatoTest vs FLI score, Area Under the Receiver-Operating Characteristics (ROC) curves (AUROC)s were 0.84 vs 0.72 vs 0.72 for the diagnosis of steatosis ≥ S1, 0.86 vs 0.73 vs 0.71 for the diagnosis of steatosis ≥ S2, and 0.93 vs 0.73 vs 0.75 for the diagnosis of steatosis S3 respectively. For a sensitivity ≥ 90%, cut-offs of CAP were 215 dB m(-1) for S ≥ 1, 252 dB m(-1) for S ≥ 2, and 296 dB m(-1) for S3. CONCLUSION: CAP is very efficient to detect even low grade steatosis. CAP being implemented on FibroScan(®) (Echosens, Paris, France), both steatosis and fibrosis can be evaluated simultaneously, enlarging the spectrum of non-invasive techniques for the management of chronic liver diseases.


Assuntos
Técnicas de Imagem por Elasticidade , Fígado Gorduroso/diagnóstico , Cirrose Hepática/diagnóstico , Fígado/diagnóstico por imagem , Adulto , Idoso , Biomarcadores/sangue , Biópsia , Índice de Massa Corporal , Doença Crônica , Ensaios Enzimáticos Clínicos , Fígado Gorduroso/sangue , Fígado Gorduroso/diagnóstico por imagem , Fígado Gorduroso/patologia , Feminino , França , Humanos , Modelos Lineares , Fígado/patologia , Cirrose Hepática/sangue , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Hepatopatia Gordurosa não Alcoólica , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...